Fire exposure, water immersion, needle penetration, and drop tests: what does an energy storage battery undergo before leaving the factory?


Online discussions about lithium-battery safety mostly stop at the question of whether they will explode. But from the cell stage to installation and shipment, a storage battery passes through an entire testing regime— Security is not a “feeling”; it is a series of tests that can be defined, executed, and reproduced. 。

This article takes you through the complete journey of a battery in a reliability laboratory. By the end, you will have gained two key capabilities: ① Understand what any battery test report is saying; ② Know what to ask the supplier for. only then can we determine whether the word “safe” is merely marketing jargon or a genuine promise.

Level 1: Environmental Testing — The battery must withstand the environmental conditions it will experience throughout its lifetime.

The lifecycle of an energy storage battery involves exposure to high temperatures, cold starts in winter, humid rainy seasons, and rough transportation. Environmental testing simulates these conditions:

High-low temperature cycling — Repeated cycling between low and high temperatures tests whether the structure of the energy storage battery pack cracks or its seals fail under thermal expansion and contraction.
High-temperature storage — Simulate full-vehicle exposure to summer sunlight to see whether the battery exhibits abnormal degradation or swelling under high temperatures;
Thermal shock — Sudden shifts from extreme cold to extreme heat are harsher than cycling and specifically target material fatigue issues;
Damp Heat Test ——High-humidity, high-temperature environment; assesses insulation and corrosion protection.
Vibration and Drop — Simulated transportation and usage shocks. Many batteries that “stop working after a while” suffer from latent structural damage that develops during this phase.

The relevant standards include the GB/T 2423 series of environmental test methods, as well as the corresponding environmental safety clauses in battery product standards.

Level 2: Electrical Safety Testing — Under Abuse Conditions, the Battery Must “Fail Gracefully”

This stage deliberately creates various abusive conditions to assess the battery’s behavior under extreme circumstances:

  1. Overcharge : Continuously charging at a voltage far exceeding the specified limit— a qualified battery management system should terminate charging, and the battery must not catch fire or explode;
  2. Overdischarge : Force discharge to the end before continuing—assessing safety after deep discharge;
  3. External short circuit : Simulate wire harness damage and conductor bridging—under high-current impact, the battery must not catch fire or explode;
  4. Over-temperature charging/discharging : Continue operation in an environment exceeding the specified temperature to verify whether the protective action is timely.

Both GB 31241-2014, which sets safety requirements for lithium batteries used in portable electronic products, and GB 31485-2015, which sets electrical safety requirements for power storage batteries, provide clear criteria for evaluating the aforementioned items: No fire, no explosion, no leakage It is a bottom-line statement.

It should be emphasized that these tests assess "The posture in failure" No technology can guarantee that a battery will never fail, but a qualified battery should exhibit a predictable, non-hazardous failure mode when it does fail. This is the engineering definition of “safety.”

Level 3: Needle Pricking — The Most Rigorous Level

The nail penetration test is known as the “Mount Everest” of battery safety tests: a steel needle is driven through the cell to artificially induce the most severe internal short circuit.

Why is it so difficult? Because internal short circuits are the hardest type of battery failure to prevent—external protection mechanisms (such as BMS overcurrent protection and fuses) are completely ineffective against a direct internal short in a cell, leaving thermal runaway to be managed solely by the cell’s materials and structural design.

There has long been debate within the industry about needle-punching (with differing criteria and practices across various standards systems), but the engineering community’s consensus remains unchanged: Needle penetration represents the ultimate test of a cell’s intrinsic safety. . In addition to acupuncture, other treatments at the same level include:

Compression test — Simulate collision and compression deformation to assess post-deformation safety;
Hot-box test ——Continuously heat the exterior and observe the thermal runaway trigger temperature and propagation behavior;
Thermal Runaway Propagation Test (Standard requirements for energy storage and power batteries) — deliberately triggering thermal runaway in a single cell to assess whether it will propagate to the entire pack. This determines the difference between “one battery cell failing” and “an entire vehicle catching fire.”

Level 4: System-Level Validation — Good Cells Do Not Equal a Good Battery Pack

Test results for individual cells cannot be directly extrapolated to the battery pack. At the battery-pack level, there is an additional set of independent issues:

  1. Consistency : Dozens or even hundreds of cells are connected in series and parallel; the weakest cell determines the overall performance of the entire pack.
  2. PACK process : Harness fixation, insulation clearance, structural strength — many accidents stem from manufacturing defects rather than the cells themselves;
  3. Potting process : At the PACK level, ginkgo employs potting technology to provide flame retardancy, waterproofing, and suppression of thermal runaway—this constitutes passive safety at the structural layer, forming a dual safeguard together with the BMS’s active monitoring;
  4. BMS Joint Debugging All protection, equalization, and estimation functions must be verified for actual effectiveness in the complete packaged state.

This is also why you should consider this when selecting a supplier. "Do you have your own laboratory?" : Manufacturers lacking testing facilities must rely on cell‑maker reports and theoretical analysis; system‑level integration issues only become apparent once the product reaches the customer.

How to interpret the report: three key identification points

When you receive a test report, first check three things:

1 Issuing Authority — Reports issued by CNAS-accredited laboratories bear the accreditation mark and certificate number, which can be verified on the CNAS website; the same applies to CMA qualification certification. “Internal test reports” without formal accreditation carry reduced evidentiary weight.
2 View the basis for the determination — Each test shall specify the relevant standard clause (e.g., Chapter X of GB 31241-2014) and the acceptance criteria; “test passed” must correspond to a specific clause.
3 View sample information — Sample model, condition (new/after cycling), quantity, and test date. A report generated using a “good‑condition prototype” is not the same as the batch you actually purchased.

What can the ginkgo laboratory do?

Hunan Ginkgo Reliability Technology Research Institute Co., Ltd. (Ginkgo Reliability Laboratory) is equipped with testing facilities for battery pack environmental safety, electrical safety, and cell/battery pack performance. It can conduct environmental, reliability, and safety tests in accordance with national standards such as GB 31241-2014, GB 31484-2015, GB 31485-2015, GB 31486-2015, and GB 31467.3-2015, and possesses:

CNAS Laboratory Accreditation · International Mutual Recognition of Reports
CMA Accreditation · Data Serves as Social Proof
ISO 9001 Quality Management System Certification

The laboratory provides testing services to external clients and also conducts design verification internally for the company’s self-produced batteries and BMS— Before leaving the factory, every Ginkgo product goes through this system. 。

Things we explicitly do not promise

① Passing a test does not guarantee absolute safety. — Testing validates known failure modes and cannot cover all unknown scenarios;

② We do not offer a "guaranteed pass" service. —The laboratory’s position is data neutrality: the results reflect whatever the data show.

③ The national standard is the floor, not the ceiling. — Passing the national standard is merely an entry requirement; achieving long life and high reliability requires further efforts on this basis.

④ A sample report is not equivalent to batch quality. — Production consistency is ensured by the production line’s quality system, not by a single report.

About the Author

The Ginkgo Reliability Laboratory is affiliated with Hunan Ginkgo Reliability Technology Research Institute Co., Ltd. (a subsidiary of Hunan Ginkgo Data Technology Co., Ltd.). It holds CNAS laboratory accreditation, CMA qualification certification, and ISO 9001 certification. The laboratory conducts environmental, reliability, and safety testing of batteries in accordance with national standards such as GB 31241, GB 31484, GB 31485, GB 31486, and GB 31467.3, and also undertakes design verification for Ginkgo’s in-house battery products and BMS.